Arrow Research search

Author name cluster

Robert Bartha

Possible papers associated with this exact author name in Arrow. This page groups case-insensitive exact name matches and is not a full identity disambiguation profile.

6 papers
1 author row

Possible papers

6

YNIMG Journal 2023 Journal Article

ROOD-MRI: Benchmarking the robustness of deep learning segmentation models to out-of-distribution and corrupted data in MRI

  • Lyndon Boone
  • Mahdi Biparva
  • Parisa Mojiri Forooshani
  • Joel Ramirez
  • Mario Masellis
  • Robert Bartha
  • Sean Symons
  • Stephen Strother

Deep artificial neural networks (DNNs) have moved to the forefront of medical image analysis due to their success in classification, segmentation, and detection challenges. A principal challenge in large-scale deployment of DNNs in neuroimage analysis is the potential for shifts in signal-to-noise ratio, contrast, resolution, and presence of artifacts from site to site due to variances in scanners and acquisition protocols. DNNs are famously susceptible to these distribution shifts in computer vision. Currently, there are no benchmarking platforms or frameworks to assess the robustness of new and existing models to specific distribution shifts in MRI, and accessible multi-site benchmarking datasets are still scarce or task-specific. To address these limitations, we propose ROOD-MRI: a novel platform for benchmarking the Robustness of DNNs to Out-Of-Distribution (OOD) data, corruptions, and artifacts in MRI. This flexible platform provides modules for generating benchmarking datasets using transforms that model distribution shifts in MRI, implementations of newly derived benchmarking metrics for image segmentation, and examples for using the methodology with new models and tasks. We apply our methodology to hippocampus, ventricle, and white matter hyperintensity segmentation in several large studies, providing the hippocampus dataset as a publicly available benchmark. By evaluating modern DNNs on these datasets, we demonstrate that they are highly susceptible to distribution shifts and corruptions in MRI. We show that while data augmentation strategies can substantially improve robustness to OOD data for anatomical segmentation tasks, modern DNNs using augmentation still lack robustness in more challenging lesion-based segmentation tasks. We finally benchmark U-Nets and vision transformers, finding robustness susceptibility to particular classes of transforms across architectures. The presented open-source platform enables generating new benchmarking datasets and comparing across models to study model design that results in improved robustness to OOD data and corruptions in MRI.

YNIMG Journal 2021 Journal Article

Resting state fMRI scanner instabilities revealed by longitudinal phantom scans in a multi-center study

  • Aras Kayvanrad
  • Stephen R. Arnott
  • Nathan Churchill
  • Stefanie Hassel
  • Aditi Chemparathy
  • Fan Dong
  • Mojdeh Zamyadi
  • Tom Gee

Quality assurance (QA) is crucial in longitudinal and/or multi-site studies, which involve the collection of data from a group of subjects over time and/or at different locations. It is important to regularly monitor the performance of the scanners over time and at different locations to detect and control for intrinsic differences (e.g., due to manufacturers) and changes in scanner performance (e.g., due to gradual component aging, software and/or hardware upgrades, etc.). As part of the Ontario Neurodegenerative Disease Research Initiative (ONDRI) and the Canadian Biomarker Integration Network in Depression (CAN-BIND), QA phantom scans were conducted approximately monthly for three to four years at 13 sites across Canada with 3T research MRI scanners. QA parameters were calculated for each scan using the functional Biomarker Imaging Research Network's (fBIRN) QA phantom and pipeline to capture between- and within-scanner variability. We also describe a QA protocol to measure the full-width-at-half-maximum (FWHM) of slice-wise point spread functions (PSF), used in conjunction with the fBIRN QA parameters. Variations in image resolution measured by the FWHM are a primary source of variance over time for many sites, as well as between sites and between manufacturers. We also identify an unexpected range of instabilities affecting individual slices in a number of scanners, which may amount to a substantial contribution of unexplained signal variance to their data. Finally, we identify a preliminary preprocessing approach to reduce this variance and/or alleviate the slice anomalies, and in a small human data set show that this change in preprocessing can have a significant impact on seed-based connectivity measurements for some individual subjects. We expect that other fMRI centres will find this approach to identifying and controlling scanner instabilities useful in similar studies.

YNICL Journal 2019 Journal Article

Linked MRI signatures of the brain's acute and persistent response to concussion in female varsity rugby players

  • Kathryn Y. Manning
  • Alberto Llera
  • Gregory A. Dekaban
  • Robert Bartha
  • Christy Barreira
  • Arthur Brown
  • Lisa Fischer
  • Tatiana Jevremovic

Acute brain changes are expected after concussion, yet there is growing evidence of persistent abnormalities well beyond clinical recovery and clearance to return to play. Multiparametric MRI is a powerful approach to non-invasively study structure-function relationships in the brain, however it remains challenging to interpret the complex and heterogeneous cascade of brain changes that manifest after concussion. Emerging conjunctive, data-driven analysis approaches like linked independent component analysis can integrate structural and functional imaging data to produce linked components that describe the shared inter-subject variance across images. These linked components not only offer the potential of a more comprehensive understanding of the underlying neurobiology of concussion, but can also provide reliable information at the level of an individual athlete. In this study, we analyzed resting-state functional MRI (rs-fMRI) and diffusion tensor imaging (DTI) within a cohort of female varsity rugby players (n = 52) through the in- and off-season, including concussed athletes (n = 21) who were studied longitudinally at three days, three months and six months after a diagnosed concussion. Linked components representing co-varying white matter microstructure and functional network connectivity characterized (a) the brain's acute response to concussion and (b) persistent alterations beyond clinical recovery. Furthermore, we demonstrate that these long-term brain changes related to specific aspects of a concussion history and allowed us to monitor individual athletes before and longitudinally after a diagnosed concussion.

YNICL Journal 2019 Journal Article

The Canadian Dementia Imaging Protocol: Harmonization validity for morphometry measurements

  • Olivier Potvin
  • Isabelle Chouinard
  • Louis Dieumegarde
  • Robert Bartha
  • Pierre Bellec
  • D. Louis Collins
  • Maxime Descoteaux
  • Rick Hoge

The harmonized Canadian Dementia Imaging Protocol (CDIP) has been developed to suit the needs of a number of co-occurring Canadian studies collecting data on brain changes across adulthood and neurodegeneration. In this study, we verify the impact of CDIP parameters compliance on total brain volume variance using 86 scans of the same individual acquired on various scanners. Data included planned data collection acquired within the Consortium pour l'identification précoce de la maladie Alzheimer - Québec (CIMA-Q) and Canadian Consortium on Neurodegeneration in Aging (CCNA) studies, as well as opportunistic data collection from various protocols. For images acquired from Philips scanners, lower variance in brain volumes were observed when the stated CDIP resolution was set. For images acquired from GE scanners, lower variance in brain volumes were noticed when TE/TR values were within 5% of the CDIP protocol, compared to values farther from that criteria. Together, these results suggest that a harmonized protocol like the CDIP may help to reduce neuromorphometric measurement variability in multi-centric studies.

YNICL Journal 2019 Journal Article

White matter integrity is associated with gait impairment and falls in mild cognitive impairment. Results from the gait and brain study

  • Jonatan A. Snir
  • Robert Bartha
  • Manuel Montero-Odasso

BACKGROUND: Mild Cognitive Impairment (MCI) is an intermediate state between normal cognition and dementia that is associated with twice the risk of falls. It is unknown whether white matter integrity (WMI) is associated with increased risk of falls in MCI. The purpose of this study was to evaluate if early changes in WMI were associated with gait impairment and falls. METHODS: Forty-three participants with MCI from the Gait and Brain Study underwent standardized assessment of cognition, gait performance under single and dual-task conditions (walking while talking), and WMI using 3 Tesla diffusion tensor imaging (DTI). Macro-structural imaging characteristics (white and grey matter morphology) as well as microstructural WMI parameters were examined for associations with falls and gait performance. Significantly associated WM tracts were then used to test the interplay between WMI and history of falls, after adjusting for other important covariates. RESULTS: Multiple WM tracts (corpus callosum, forceps minor, and the left inferior fronto-occipital fasciculus) were significantly associated with history of falls and lower dual-task gait performance. A multivariable regression model showed that fall history was associated with the radial diffusivity in the forceps minor, even after adjusting for education, sex, BMI, MMSE scores, comorbidities, gait velocity and WMH volume as covariates. CONCLUSIONS: Multiple WM tracts that are known to be involved in executive and visuospatial functions were preferentially affected in MCI individuals with history of falls. Our preliminary findings support the notion that WMI in key brain regions may increase risk of falls in older adults with MCI.

YNIMG Journal 2006 Journal Article

Linear aspects of transformation from interictal epileptic discharges to BOLD fMRI signals in an animal model of occipital epilepsy

  • Seyed M. Mirsattari
  • Zheng Wang
  • John R. Ives
  • Frank Bihari
  • L. Stan Leung
  • Robert Bartha
  • Ravi S. Menon

Epileptic disorders manifest with seizures and interictal epileptic discharges (IEDs). The hemodynamic changes that accompany IEDs are poorly understood and may be critical for understanding epileptogenesis. Despite a known linear coupling of the neurovascular elements in normal brain tissues, previous simultaneous electroencephalography (EEG)–functional magnetic resonance imaging (fMRI) studies have shown variable correlations between epileptic discharges and blood oxygenation level-dependent (BOLD) response, partly because most previous studies assumed particular hemodynamic properties in normal brain tissue. The occurrence of IEDs in human subjects is unpredictable. Therefore, an animal model with reproducible stereotyped IEDs was developed by the focal injection of penicillin into the right occipital cortex of rats anesthetized with isoflurane. Simultaneous EEG–fMRI was used to study the hemodynamic changes during IEDs. A hybrid of temporal independent component analysis (ICA) of EEG and spatial ICA of fMRI data was used to correlate BOLD fMRI signals with IEDs. A linear autoregression with exogenous input (ARX) model was used to estimate the hemodynamic impulse response function (HIRF) based on the data from simultaneous EEG–fMRI measurement. Changes in the measured BOLD signal from the right primary visual cortex and bilateral visual association cortices were consistently coupled to IEDs. The linear ARX model was applied here to confirm that a linear transform can be used to study the correlation between BOLD signal and its corresponding neural activity in this animal model of occipital epilepsy.

v2026.09.13