Arrow Research search

Author name cluster

James Osborne

Possible papers associated with this exact author name in Arrow. This page groups case-insensitive exact name matches and is not a full identity disambiguation profile.

9 papers
1 author row

Possible papers

9

YNICL Journal 2025 Journal Article

OPM-MEG in multiple sclerosis: Proof of principle, and the effect of naturalistic posture

  • Benjamin J. Sanders
  • Christopher G.S. Gilmartin
  • Lukas Rier
  • Lauren Gascoyne
  • Emily McCann
  • Jorge Cabrera
  • James Leggett
  • Niall Holmes

Multiple Sclerosis (MS) is a common neurological disorder in which myelin damage affects neuronal signalling. Magnetoencephalography (MEG - the measurement of magnetic fields generated by neuronal currents) offers metrics of brain function that relate directly to electrophysiological signalling, making it a valuable tool for exploring how abnormal function relates to MS symptoms. However, conventional MEG requires participants to be seated or supine with limited head and body motion. This makes it hard to measure brain function whilst simultaneously asking patients to carry out tasks they find challenging - many of which relate to movement. Here, we used a newly developed OPM-MEG system, with a wearable helmet and a lightweight backpack-mounted control unit, to measure MEG signals in people with MS (pwMS), both at rest and during a visuo-motor task. Uniquely, our system enabled data collection in participants who were seated and standing. We found that established markers of MS - including delayed beta-band responses to finger movement and diminished gamma-band responses to visual stimulation - were measurable using OPM-MEG. Further, we showed that standing (compared to sitting) decreased beta-band connectivity (in patients and controls, but the effect was only significant in controls) and decreased oscillatory power (in patients but not controls). In summary, our paper confirms that OPM-MEG is a useful means to investigate MS; it also demonstrates the importance of investigating how changes in posture relate to oscillations and connectivity, and lays the groundwork for broader studies of movement.

YNIMG Journal 2023 Journal Article

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding

  • Niall Holmes
  • Molly Rea
  • Ryan M. Hill
  • James Leggett
  • Lucy J. Edwards
  • Peter J. Hobson
  • Elena Boto
  • Tim M. Tierney

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.

YNIMG Journal 2023 Journal Article

Measurement of Frontal Midline Theta Oscillations using OPM-MEG

  • Natalie Rhodes
  • Molly Rea
  • Elena Boto
  • Lukas Rier
  • Vishal Shah
  • Ryan M. Hill
  • James Osborne
  • Cody Doyle

Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over conventional instrumentation. However, when trying to measure signals at low frequency, higher levels of inherent sensor noise, magnetic interference and movement artefact introduce a significant challenge. Accurate characterisation of low frequency brain signals is important for neuroscientific, clinical, and paediatric MEG applications and consequently, demonstrating the viability of OPMs in this area is critical. Here, we undertake measurement of theta band (4-8 Hz) neural oscillations and contrast a newly developed 174 channel triaxial wearable OPM-MEG system with conventional (cryogenic-MEG) instrumentation. Our results show that visual steady state responses at 4 Hz, 6 Hz and 8 Hz can be recorded using OPM-MEG with a signal-to-noise ratio (SNR) that is not significantly different to conventional MEG. Moreover, we measure frontal midline theta oscillations during a 2-back working memory task, again demonstrating comparable SNR for both systems. We show that individual differences in both the amplitude and spatial signature of induced frontal-midline theta responses are maintained across systems. Finally, we show that our OPM-MEG results could not have been achieved without a triaxial sensor array, or the use of postprocessing techniques. Our results demonstrate the viability of OPMs for characterising theta oscillations and add weight to the argument that OPMs can replace cryogenic sensors as the fundamental building block of MEG systems.

YNIMG Journal 2022 Journal Article

Triaxial detection of the neuromagnetic field using optically-pumped magnetometry: feasibility and application in children

  • Elena Boto
  • Vishal Shah
  • Ryan M. Hill
  • Natalie Rhodes
  • James Osborne
  • Cody Doyle
  • Niall Holmes
  • Molly Rea

Optically-pumped magnetometers (OPMs) are an established alternative to superconducting sensors for magnetoencephalography (MEG), offering significant advantages including flexibility to accommodate any head size, uniform coverage, free movement during scanning, better data quality and lower cost. However, OPM sensor technology remains under development; there is flexibility regarding OPM design and it is not yet clear which variant will prove most effective for MEG. Most OPM-MEG implementations have either used single-axis (equivalent to conventional MEG) or dual-axis magnetic field measurements. Here we demonstrate use of a triaxial OPM formulation, able to characterise the full 3D neuromagnetic field vector. We show that this novel sensor is able to characterise magnetic fields with high accuracy and sensitivity that matches conventional (dual-axis) OPMs. We show practicality via measurement of biomagnetic fields from both the heart and the brain. Using simulations, we demonstrate how triaxial measurement offers improved cortical coverage, especially in infants. Finally, we introduce a new 3D-printed child-friendly OPM-helmet and demonstrate feasibility of triaxial measurement in a five-year-old. In sum, the data presented demonstrate that triaxial OPMs offer a significant improvement over dual-axis variants and are likely to become the sensor of choice for future MEG systems, particularly for deployment in paediatric populations.

YNIMG Journal 2022 Journal Article

Using OPM-MEG in contrasting magnetic environments

  • Ryan M. Hill
  • Jasen Devasagayam
  • Niall Holmes
  • Elena Boto
  • Vishal Shah
  • James Osborne
  • Kristina Safar
  • Frank Worcester

Magnetoencephalography (MEG) has been revolutionised by optically pumped magnetometers (OPMs). "OPM-MEG" offers higher sensitivity, better spatial resolution, and lower cost than conventional instrumentation based on superconducting quantum interference devices (SQUIDs). Moreover, because OPMs are small, lightweight, and portable they offer the possibility of lifespan compliance and (with control of background field) motion robustness, dramatically expanding the range of MEG applications. However, OPM-MEG remains nascent technology; it places stringent requirements on magnetic shielding, and whilst a number of viable systems exist, most are custom made and there have been no cross-site investigations showing the reliability of data. In this paper, we undertake the first cross-site OPM-MEG comparison, using near identical commercial systems scanning the same participant. The two sites are deliberately contrasting, with different magnetic environments: a "green field" campus university site with an OPM-optimised shielded room (low interference) and a city centre hospital site with a "standard" (non-optimised) MSR (higher interference). We show that despite a 20-fold difference in background field, and a 30-fold difference in low frequency interference, using dynamic field control and software-based suppression of interference we can generate comparable noise floors at both sites. In human data recorded during a visuo-motor task and a face processing paradigm, we were able to generate similar data, with source localisation showing that brain regions could be pinpointed with just ∼10 mm spatial discrepancy and temporal correlations of > 80%. Overall, our study demonstrates that, with appropriate field control, OPM-MEG systems can be sited even in city centre hospital locations. The methods presented pave the way for wider deployment of OPM-MEG.

YNIMG Journal 2021 Journal Article

Measuring functional connectivity with wearable MEG

  • Elena Boto
  • Ryan M. Hill
  • Molly Rea
  • Niall Holmes
  • Zelekha A. Seedat
  • James Leggett
  • Vishal Shah
  • James Osborne

Optically-pumped magnetometers (OPMs) offer the potential for a step change in magnetoencephalography (MEG) enabling wearable systems that provide improved data quality, accommodate any subject group, allow data capture during movement and potentially reduce cost. However, OPM-MEG is a nascent technology and, to realise its potential, it must be shown to facilitate key neuroscientific measurements, such as the characterisation of brain networks. Networks, and the connectivities that underlie them, have become a core area of neuroscientific investigation, and their importance is underscored by many demonstrations of their disruption in brain disorders. Consequently, a demonstration of network measurements using OPM-MEG would be a significant step forward. Here, we aimed to show that a wearable 50-channel OPM-MEG system enables characterisation of the electrophysiological connectome. To this end, we measured connectivity in the resting state and during a visuo-motor task, using both OPM-MEG and a state-of-the-art 275-channel cryogenic MEG device. Our results show that resting-state connectome matrices from OPM and cryogenic systems exhibit a high degree of similarity, with correlation values >70%. In addition, in task data, similar differences in connectivity between individuals (scanned multiple times) were observed in cryogenic and OPM-MEG data, again demonstrating the fidelity of the OPM-MEG device. This is the first demonstration of network connectivity measured using OPM-MEG, and results add weight to the argument that OPMs will ultimately supersede cryogenic sensors for MEG measurement.

YNIMG Journal 2021 Journal Article

Precision magnetic field modelling and control for wearable magnetoencephalography

  • Molly Rea
  • Niall Holmes
  • Ryan M. Hill
  • Elena Boto
  • James Leggett
  • Lucy J. Edwards
  • David Woolger
  • Eliot Dawson

Optically-pumped magnetometers (OPMs) are highly sensitive, compact magnetic field sensors, which offer a viable alternative to cryogenic sensors (superconducting quantum interference devices - SQUIDs) for magnetoencephalography (MEG). With the promise of a wearable system that offers lifespan compliance, enables movement during scanning, and provides higher quality data, OPMs could drive a step change in MEG instrumentation. However, this potential can only be realised if background magnetic fields are appropriately controlled, via a combination of optimised passive magnetic screening (i.e. enclosing the system in layers of high-permeability materials), and electromagnetic coils to further null the remnant magnetic field. In this work, we show that even in an OPM-optimised passive shield with extremely low (<2 nT) remnant magnetic field, head movement generates significant artefacts in MEG data that manifest as low-frequency interference. To counter this effect we introduce a magnetic field mapping technique, in which the participant moves their head to sample the background magnetic field using a wearable sensor array; resulting data are compared to a model to derive coefficients representing three uniform magnetic field components and five magnetic field gradient components inside the passive shield. We show that this technique accurately reconstructs the magnitude of known magnetic fields. Moreover, by feeding the obtained coefficients into a bi-planar electromagnetic coil system, we were able to reduce the uniform magnetic field experienced by the array from a magnitude of 1.3±0.3 nT to 0.29±0.07 nT. Most importantly, we show that this field compensation generates a five-fold reduction in motion artefact at 0‒2 Hz, in a visual steady-state evoked response experiment using 6 Hz stimulation. We suggest that this technique could be used in future OPM-MEG experiments to improve the quality of data, especially in paradigms seeking to measure low-frequency oscillations, or in experiments where head movement is encouraged.

YNIMG Journal 2021 Journal Article

Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system

  • Matthew J. Brookes
  • Elena Boto
  • Molly Rea
  • Vishal Shah
  • James Osborne
  • Niall Holmes
  • Ryan M. Hill
  • James Leggett

The optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a "wearable" scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality. Although many studies have shown the efficacy of 'OPM-MEG', one relatively untapped advantage relates to improved array design. Specifically, OPMs enable the simultaneous measurement of magnetic field components along multiple axes (distinct from a single radial orientation, as used in most conventional MEG systems). This enables characterisation of the magnetic field vector at all sensors, affording extra information which has the potential to improve source reconstruction. Here, we conduct a theoretical analysis of the critical parameters that should be optimised for effective source reconstruction. We show that these parameters can be optimised by judicious array design incorporating triaxial MEG measurements. Using simulations, we demonstrate how a triaxial array offers a dramatic improvement on our ability to differentiate real brain activity from sources of magnetic interference (external to the brain). Further, a triaxial system is shown to offer a marked improvement in the elimination of artefact caused by head movement. Theoretical results are supplemented by an experimental recording demonstrating improved interference reduction. These findings offer new insights into how future OPM-MEG arrays can be designed with improved performance.

YNIMG Journal 2020 Journal Article

Multi-channel whole-head OPM-MEG: Helmet design and a comparison with a conventional system

  • Ryan M. Hill
  • Elena Boto
  • Molly Rea
  • Niall Holmes
  • James Leggett
  • Laurence A. Coles
  • Manolis Papastavrou
  • Sarah K. Everton

Magnetoencephalography (MEG) is a powerful technique for functional neuroimaging, offering a non-invasive window on brain electrophysiology. MEG systems have traditionally been based on cryogenic sensors which detect the small extracranial magnetic fields generated by synchronised current in neuronal assemblies, however, such systems have fundamental limitations. In recent years, non-cryogenic quantum-enabled sensors, called optically-pumped magnetometers (OPMs), in combination with novel techniques for accurate background magnetic field control, have promised to lift those restrictions offering an adaptable, motion-robust MEG system, with improved data quality, at reduced cost. However, OPM-MEG remains a nascent technology, and whilst viable systems exist, most employ small numbers of sensors sited above targeted brain regions. Here, building on previous work, we construct a wearable OPM-MEG system with ‘whole-head’ coverage based upon commercially available OPMs, and test its capabilities to measure alpha, beta and gamma oscillations. We design two methods for OPM mounting; a flexible (EEG-like) cap and rigid (additively-manufactured) helmet. Whilst both designs allow for high quality data to be collected, we argue that the rigid helmet offers a more robust option with significant advantages for reconstruction of field data into 3D images of changes in neuronal current. Using repeat measurements in two participants, we show signal detection for our device to be highly robust. Moreover, via application of source-space modelling, we show that, despite having 5 times fewer sensors, our system exhibits comparable performance to an established cryogenic MEG device. While significant challenges still remain, these developments provide further evidence that OPM-MEG is likely to facilitate a step change for functional neuroimaging.

v2026.09.13